3-28 Compaq ProLiant ML370 Maintenance and Service Guide
200-299, Memory Test Error Codes
The 200 series of diagnostic error codes identifies failures with the memory subsystem.
Table 3-4
Memory Test Error Codes
Error Code Description Recommended Action
200-xx Invalid memory configuration. Reinsert memory modules in correct location and retest.
201-xx Memory machine ID test failed.
202-xx Memory system ROM checksum
failed.
1. Replace the system ROM and retest.
2. Replace the processor board and retest.
3. Replace the memory expansion board and retest.
203-xx Memory write/read test failed.
204-xx Memory address test failed.
205-xx Walking I/O test failed.
206-xx Increment pattern test failed
1. Replace the memory module and retest.
2. Replace the processor board and retest.
3. Replace the memory expansion board and retest.
207-xx Invalid memory
configuration-check DIMM
installation. DIMMs installed
have 8K refresh.
Replace DIMMs.
208-xx Invalid memory speed detected -
check DIMM installation. Slow
DIMMs may cause data loss.
Replace DIMMs with timing greater than 60 ns.
209-01 RAM long test failed.
209-02 Error while saving test block.
209-03 Error while restoring test block.
209-89 ECC error during testing.
1. Replace the memory module/board and retest.
2. Replace the system board and retest.
3. Replace the memory expansion board and retest.
210-xx Random pattern test failed. 1. Replace the memory module and retest.
2. Replace the processor board and retest.
3. Replace the memory expansion board and retest.
211-01 RAND test failed.
211-02 Error while saving test block
211-03 Error while restoring test block
211-04 Insufficient memory to perform the
test
211-05 Failed inverted pattern compare,
but RAM was correct
211-89 ECC error during testing
1. Replace the memory module/board and retest.
2. Replace the system board and retest.
214-01 Data error during noise test
214-89 ECC error during testing
1. Replace the memory module/board and retest.
2. Replace the system board and retest.
215 Non-functioning DC-DC converter
for processor X
Replace the DC-DC converter (Processor Power
Module).

Table of Contents

Other manuals for Compaq PROLIANT ML370

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Compaq PROLIANT ML370 and is the answer not in the manual?

Compaq PROLIANT ML370 Specifications

General IconGeneral
BrandCompaq
ModelPROLIANT ML370
CategoryServer
LanguageEnglish

Related product manuals