EasyManua.ls Logo

Comtech EF Data HPOD - Page 143

Comtech EF Data HPOD
156 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier Revision 6
Appendix B MN/HPOD.IOM
B–7
Redundancy State and Mode
UsethedropdownlisttosettheRedundancyStateasOff,1:1,or1:2.
UsethedropdownlisttosettheRedundancyModeasManualorAutomatic.
Click[Change]tosavethesesettings.
Set Switch Position (1:1 only)
In Manual Mode only To force a unit into the active online state, use the dropdown list to
selectaunitnumber,andthenclick[SendtheCommand].
Gain Offset (1:1 only)
Enterthegainoffset,in0.25dBsteps,andthenclick[Change].
Force Back-up State (1:2 only)
Usethedropdownlisttosetthebackupstateasfollows:
Select Unit 01 or Unit 02 to put that HPOD into an offline state and set the Redundancy
ModetoManual.
SelectNonetoputthebackupunitofflineandsettheRedundancyModetoA
utomatic.
Click[Change]tosavethissetting.
Backup Offset for Unit 01 (1:2 only)
EntertheBackupOffsetforUnit01,in0.25dBsteps,andthenclick[Change].
Backup Offset for Unit 02 (1:2 only)
EntertheBackupOffsetforUnit02,in0.25dBsteps,andthenclick[Change].
Online Status
TheactivestatusfortheunitisidentifiedhereasOnlineorOffline.
.

Table of Contents

Related product manuals