HPOD C-, X-, Ku-Band High-Power Outdoor Amplifier Revision 6
Appendix B MN/HPOD.IOM
B–7
Redundancy State and Mode
• Usethedrop‐downlisttosettheRedundancyStateasOff,1:1,or1:2.
• Usethedrop‐downlisttosettheRedundancyModeasManualorAutomatic.
Click[Change]tosavethesesettings.
Set Switch Position (1:1 only)
In Manual Mode only – To force a unit into the active online state, use the drop‐down list to
selectaunitnumber,andthenclick[SendtheCommand].
Gain Offset (1:1 only)
Enterthegainoffset,in0.25dBsteps,andthenclick[Change].
Force Back-up State (1:2 only)
Usethedrop‐downlisttosettheback‐upstateasfollows:
• Select Unit 01 or Unit 02 to put that HPOD into an offline state and set the Redundancy
ModetoManual.
• SelectNonetoputthebackupunitofflineandsettheRedundancyModetoA
utomatic.
Click[Change]tosavethissetting.
Backup Offset for Unit 01 (1:2 only)
EntertheBackupOffsetforUnit01,in0.25dBsteps,andthenclick[Change].
Backup Offset for Unit 02 (1:2 only)
EntertheBackupOffsetforUnit02,in0.25dBsteps,andthenclick[Change].
Online Status
TheactivestatusfortheunitisidentifiedhereasOnlineorOffline.
.