It is used for the communication with strain gauge amplifier. The signal level
is an equivalent for RS-422. There is no necessity for connection in the system
without a load cell.
Cable type:CBSLC-**M(Basic Cable)
Cable type:JCBSLC-**M(Joint Cable)
An origin sensor is connected. Although, as for this system, absolute encoder
specification is also prepared, all tools are equipped with the origin sensor for
the initial position setup.
Cable type:CBSGS-**M
MR-J3A parallel i/f(CN33)
It connects with CN1 of MR-J3A. The position detection pulse of a motor and
the position instruction pulse to MR-J3A are contained. In order to avoid the
influence of a noise, short wiring is recommended as much as possible.
Cable type:CBSPIF-**M
An emergency stop SW is connected. The logic is normally closed. If it is made
opened, an emergency stop will be output to MR-J3A.