BS Controller for AC SERVO PRESS
Instruction Manual Ver1.08
BS-M3A-1B
- 24 -
Input
Program execution is interrupted, then a scram is carried
out. After performing speed zero for 0.2 seconds, it will be
Alarm release and judgment output reset.
Origin is started. Original position information
disappears by start of origin.
Program execution is started.
Bit 0 of JOG speed specification binaries/user input 0,
are superposed.
When JOG_ENA is ON, JOG speed is
specified in four stages with the input bit 6. When
JOG_ENA is off, it becomes the user input 0.
Bit 1 of JOG speed specification binaries/user input 1,
are superposed.
JOG operation is permitted. Moreover, the output bit 3 is
changed to BAT.ALARM.
The bit 0 of the binary value which specifies an execution
program number/+ Direction JOG are superposed. When
JOG_ENA is ON, JOG operation is carried out in the
direction of +.
The bit 1 of the binary value which specifies an execution
program number/- Direction JOG are superposed
. When
JOG_ENA is ON, JOG operation is carried out in the
direction of -.
The bit 2 of the binary value which specifies an execution
program number.
The bit 3 of the binary value which specifies an execution
program number.
The bit 4 of the binary value which specifies an execution
program number.
Servo-on is directed to MR-J3A. In operation by PI/O,
unless it is in a servo-on state, a system does not operate
*1 On the tool operation screen and a program execution screen of BS Configurator,
SERVO_ON signal are ignored.