BS Controller for AC SERVO PRESS
Instruction Manual Ver1.08
BS-M3A-1B
- 67 -
Article of Consumption
18.1.
The visual check of the abnormalities in a battery can be carried out by blink of
LED3 STATUS in the front panel upper part of a controller.
Moreover, since a battery unusual signal is outputted also from a
general-purpose output, it is detectable also by PLC.
Although the life of a backup battery is about five years, it varies greatly
according to a state of operation and environment of operation. If the
abnormalities in a battery occur, please exchange a backup battery quickly.
Battery exchange is carried out in the state of power supply ON. If batteries
are exchanged in the state of power supply off, a backup circuit will not operate
normally but consumption of a battery will progress remarkably.
Exchange date of a backup battery is memorized in a controller by BS
Configurator, and a monitor of it is possible. Moreover, calculation of the net
backup time is count. Please use it for management of a backup battery.
This controller is equipped with the clock function. In the case of battery
exchange, we recommend you to setup of a date and time.
Parts having service lives of MR-J3A
Please refer to the collection of servo amplifier technical data of MR-J3A for
details.
Number of power-on and number of
emergency
stop times : 100,000 times
10,000 to 30,000hours (2 to 3 years)
Absolute position battery
Approx. 10,000 hours (battery life with
power off)