156 4-Series™ Control Systems Product Manual Doc. 8559B
Time and Date Settings
The internal clock of the control system can be configured using console commands.
1.
Issue the timedate command to manually set the time and date.
l
Syntax: timedate [hh:mm:ss mm-dd-yyyy]
o
For hh:mm:ss, enter the time in hours (using 24-hour format), minutes, and
seconds format.
o
For mm-dd-yyyy (or mm/dd/yyyy), enter the date in month (1–12), day (1–31),
and year format.
l
Example: timedate 12:18:30 03-14-2021
2.
Issue the timezone command to set the time zone:
l
Syntax: timezone [list | zone]
o
For zone, enter the three-digit code for the time zone.
o
Use the list parameter to print a list of all time zones and their codes in the
console.
l
Example: timezone 014
3.
Issue the sntp start command to synchronize the internal clock with an SNTP server:
l
Syntax: sntp start [server:address]
o
For server:, enter the address (in dot decimal notation) of the SNTP server.
l
Example: sntp start server:255.255.255.255
The internal clock can also be set using the System Clock function in Crestron Toolbox. For more