EasyManua.ls Logo

Crestron Electronics CP4N - Session Timeout Functions

Default Icon
220 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Product Manual Doc. 8559B 4-Series™ Control Systems 165
Session Timeout Functions
By default, a user is never logged off automatically unless the value for the logon session timeout
is manually changed.
If the value for logon session timeout has been changed, the console starts a timer after a user
logs in and monitors the user's activities. If a user is idle for more than a set duration, the console
logs the user out automatically.
Change Session Timeout Duration
To change the duration for the logon session timeout, issue the setlogoffidletime command.
l
Syntax: setlogoffidletime [minutes]
o
minutes - The duration (in minutes) that must elapse before the console logs off an
idle user. Entering 0 prevents the user from being logged off automatically. The
default value is “20."
o
No parameter - Displays the current timeout setting
l
Example: setlogoffidletime 30
Change Login Failure Count
To change the value for the logon failure count, issue the setloginattempts command.
l
Syntax:setloginattempts [number]
o
number - The number of login attempts allowed before the console is blocked.
Entering 0 allows unlimited attempts. The default value is “3.”
o
No parameter - Displays the current setting
l
Example: setloginattempts 3

Table of Contents