DXS-3400 Series Lite Layer 3 Stackable 10GbE Managed Switch Web UI Reference Guide
147
Parameter Description
the None radio button to revert this parameter to the default setting.
Activate
Select the checkbox and then select whether or not to active this ERP instance.
Options to choose from are Enabled and Disabled. Enabling this option will
active this ERP instance.
Sub Ring Instance
Select and enter the sub-ring instance ID here. The range is from 1 to 32. Select
the Specify radio button to configure this parameter as per normal. Select the
None radio button to revert this parameter to the default setting.
Force Ring Port Block
Select the ERP instance port that will be blocked here. This forcibly blocks an
instance port immediately after force is configured, irrespective of whether link
failures have occurred. Options to choose from are Port0 and Port1.
Manual Ring Port Block
Select the ERP instance port that will be blocked here. This forcibly blocks a port
on which MS is configured when link failures and FS conditions are absent.
Options to choose from are Port0 and Port1.
Click the Back button to discard the changes made and return to the previous window.
Click the Apply button to accept the changes made.
ERPS Profile
This window is used to display and configure the Ethernet Ring G.8032 profile settings.
To view the following window, click L2 Features > ERPS (G.8032) > ERPS Profile, as shown below:
Figure 5-57 ERPS Profile Window
The fields that can be configured are described below:
Parameter Description
Profile Name
Enter the G.8032 profile’s name here. This name can be up to 32 characters long.
Multiple ERP instances can be associated with the same G.8032 profile. The
instances associated with the same profile protect the same set of VLANs, or the
VLANs protected by one instance are a subset of LANs protected by another
instance.
Click the Apply button to associate the G.8032 profile with the ERP instance created.
Click the Edit button to modify the specified G.8032 profile.
Click the Delete button to disassociate the G.8032 profile.
Enter a page number and click the Go button to navigate to a specific page when multiple pages exist.
After click the Edit button, the following window will appear.

Table of Contents

Other manuals for D-Link DXS-3400 SERIES

Related product manuals