95XF series Removal and installation
EXPLANATORY NOTES ON THE MAINTENANCE ACTIVITIES
4-11
VF engine
Removing the coolant filter
1. Place a tray beneath the coolant filter to
collect any escaping coolant.
2. Remove the filler cap from the expansion
tank.
3. Switch the shut-off valve to the “OFF”
position. This is the horizontal position.
4. Remove the coolant filter by turning it
counter-clockwise.
Installing the coolant filter
1. Clean the sealing face of the coolant filter.
2. Apply a small amount of coolant to the seal
of the c oolant filter element.
3. Fit the c oolant filter so that the seal makes
contact. Then tighten the filter by hand ½-
to ¾-of a turn.
4. Switch the shut-off valve to the “ON”
position. This is the vertical position.
5. Fit the f iller cap on the expansion tank.
6. Run the engine and check that the coolant
filter has sealed correctly.
7. Check the coolant level.
O