SiEBE18-526 Field Setting
Test Operation 121
Image of operation in the case of A
Image of operation in the case of B
Image of operation in the case of A, B
Operation sound
Rated operation
sound
Operation sound of
mode 1
Operation sound of
mode 2
Operation sound of
mode 3
Low noise of approx. 5 to 8 dB
(The power consumption may
be decreased by about 30%)
Operation sound level set with External low noise setting
Low noise mode instructing
If capacity precedence isset in
C
apacity precedence setting,
the fan speed will be increased
according to the load of air
conditioning when load is heavier.
Operation sound during low
noise mode is instructed can
be set with External low
noise level setting
(Factory setting is“Mode 2.)
(V3169)
Low noise of approx. 3 to 5 dB
(The power consumption may
be decreased by about 20%)
Low noise of approx. 2 to 3 dB
(The power consumption may
be decreased by about 10%)
Operation sound
Rated operation
sound
Operation sound
of mode 1
Operation sound
of mode 2
Operation sound
of mode 3
Operation sound level set with
Night quiet mode setting
Time set with Night quiet mode end setting
Time set with Night quiet mode start setting
AM 6:00
Night time
AM 7:00 AM 8:00
Set with Night quiet mode end setting.
(Factory setting i
s“AM 8:00.)
PM 8:00 PM 10:00 PM 0:00
Set with Night quiet mode start setting.
(Factory setting is“PM 10:00.)
If capacity precedence isset in Capacity
precedence setting, the fan speed will be
increased according to the load of air
conditioning when load is heavier.
Operation sound during
Night quiet mode is
instructed can be set with
Night quiet mode level
s
etting
(Factory setting is“OFF.)
(Q0399)
Oper
ation sound
Rated operation
sound
Operation sound
of mode 1
Operation sound
of mode 2
Operation sound
of mode 3
Low noise mode instructing
Operation sound set with
External low noise setting
* Operation sound
level set with
Night quiet mode
setting
* Operation sound set with
External low noise s
etting
Time set with Night quiet mode end setting
Time set with Night quiet mode start setting
AM 6:00
* Night time
* Low noise mode
instructing
AM 7:00 AM 8:00
Set with Night quiet mode end setting.
(Factory setting is“AM 8:00.)
PM 8:00 PM 10:00 PM 0:00
Set with Night quiet mode start setting.
(Factory setting is“PM 10:00.)
If capacity precedence isset in
Capacity
precedence setting, the fan speed will be
increased according to the load of air
conditioning when load is heavier.
Operation sound during low noise
mode is instructed can be set with
External low noise level setting
(Factory setting is“Mode 2.)
Operation sound during Night quiet
mode is instructed can be set with
Night quiet mode level setting
(F
actory setting is“OFF.)
When external low noise
instruction is receivied during
the operation with night-time
low noise mode.
Mode 2 precedes Mode 1 and
Mode 3 precedes Mode 2.
(Q0400)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Super Multi Plus D-Series and is the answer not in the manual?

Daikin Super Multi Plus D-Series Specifications

General IconGeneral
BrandDaikin
ModelSuper Multi Plus D-Series
CategoryHeat Pump
LanguageEnglish

Related product manuals