EasyManuals Logo

Daikin Super Multi Plus D-Series User Manual

Daikin Super Multi Plus D-Series
395 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #207 background imageLoading...
Page #207 background image
Instruction SiEBE18-526
196 System Configuration
NOTE
• Operation with dirty filters:
(1) cannot deodorize the air. (2) cannot clean the air.
(3) results in poor heating or cooling. (4) may cause odour.
To order Tita niu m Apa tite Photoca talytic Air-Purifying Filter contact to the service shop
there youbought the air conditioner.
• Dispose of old filtersasburnable waste.
Item Part No.
Titanium Apatite Photocatalytic Air-Purifying Filter.
(without frame) 1 set
KAF970A46
Check
Check that the base, sta nd and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inletsand the outlets of the indoor unit and the outdoor unit.
Check that the drain comessmoothly out of the drain hose du ring COOL or DRY operation.
If no drain water isseen, water may be leaking from the indoor unit. Stop operation and consult the
service shop if this is the case.
Before a long idle period
1. Operate the “FAN only” for several hours on a fine day to dry out the
inside.
Press MODE selector button”and select FAN operation.
Press ON/OFF button”and start operation.
2. Clean the air filters and set them again.
3. Take out batteries from the remote control.
4. Turn OFF the breaker for the room air conditioner.
When a multi outdoor unit is connected, make sure the heating operation is not used at the
other room before youuse the fan operation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Super Multi Plus D-Series and is the answer not in the manual?

Daikin Super Multi Plus D-Series Specifications

General IconGeneral
BrandDaikin
ModelSuper Multi Plus D-Series
CategoryHeat Pump
LanguageEnglish

Related product manuals