EasyManua.ls Logo

Daktronics OMNISPORT 2000 - Judge Consoles; Console Setup; Diving Event Operation; Score Editing

Default Icon
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Judge Consoles
83
7 Judge Consoles
Reference Drawings:
OmniSport 2000 and JC-100 Equipment .......................................................... DWG-189089
OmniSport 2000 Judging Equipment- In-Deck ................................................ DWG-190817
System Riser: RC-100- Rodeo/Diving/Sync Swimming .................................... DWG-230608
System Riser: RC-200- Rodeo/Diving/Sync Swimming .................................. DWG-3640329
Judge consoles are used to enter scores during diving and synchronized swimming
events. The OmniSport 2000 console can be set up to operate with 2, 3, 5, 7, or 9 judge
consoles for diving and synchronized swimming; or 7, 9, or 11 for synchronized diving. The
consoles are connected to the J14 or J15 ports on the back of the console. If wireless
judge consoles are used, a wireless base station is connected to the J14 or J15 ports on
the back of the OmniSport 2000 console.
Refer to DWG-189089 for on-deck connection details or DWG-190817 for in-deck
connection details. Refer to DWG-230608 or DWG-3640329 for wireless connection details.
For more information on the RC-100 or RC-200 consoles, refer to their operation manuals,
available online at www.daktronics.com/manuals:
Remote Control System RC-100 All Sport Operation Manual (ED-15133)
Remote Control System RC-200 All Sport Operation Manual (DD3572889)
Console Setup
The rst time a judge console (Figure 54) is connected to the
OmniSport 2000 timer it will prompt the user to enter a judge
number.
The LCD on the judge console prompts the user to enter a
number from one to the maximum number of judge’s consoles
the OmniSport 2000 console has been congured to use. If
a number is entered that has already been used by another
judge or is higher than the number of judges congured, the
console will beep and wait for a new number to be entered.
ENTER JUDGE #
-- *
JUDGE 1:
Once a judge number has been set for the judge’s console, it will appear on the LCD.
This information is the same for the JC-100, RC-100, and RC-200 console.
Diving Event Operation
The request for scores will show on the judge consoles when
the OmniSport 2000 console has entered scoring mode for
the dive. Refer to Operation During Event (p.66). The dive
number and degree-of-difculty (DD) will also be displayed.
Enter the score for the current dive, then press [ENTER] to accept. When the score has
been entered, OK appears to the left of the JUDGE number.
Score Editing
After a score has been entered, it may be changed by pressing [RE-ENTER/EDIT] on the
JC-100 (or [EDIT] on the RC-100/RC-200). This puts the console back into the scoring mode
to allow the score to be re-entered. The score cannot be edited if the OmniSport 2000
console operator has already accepted the judge’s scores.
Figure 54: JC-100 Console
JUDGE 1: 6.0*
DIVE 101A DD1.4