EasyManuals Logo

Danfoss TTS300 User Manual

Danfoss TTS300
294 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #269 background imageLoading...
Page #269 background image
5.4 SMT Compressor Connection Status Indications
l
Disconnected:noconnectionexistswithacompressororremotecompressorhost
l
ReadytoConnect:aconnectionwitharemotehost(ifapplicable)hasbeenestablished,butno
compressorconnectionhasyetbeenestablished
l
Compressorisstartingup:Thecurrentlyconnectedcompressorisinstartupmode
l
Connected:Therehasbeenestablishedaconnectionwitharemotehost(ifapplicable)anda
connectionwithacompressorhasbeenestablishedandverified
l
Nocompressorfound:Anyserialportsorconnectionshavebeenestablished,butavalid
compressorconnectionwasnotabletobedetected
l
Erroropeningport:Therewasanerroropeningthespecifiedserialport(eithertheportisalreadyin
use,theportnamedoesn’texist,ortherewassomeothererrorattemptingtoopentheserialport)
l
Servernotfound:Couldnotconnecttoremotehost
5.5 System and Compressor Level Troubleshooting
5.5.1 Compressor Voltage Troubleshooting
1. Carefully,removetheMainsInputCover.
2. Verifyallthree(3)phasesofvoltagebeforethemainsfuses.RefertoSection4.11.1.13-PhaseACinput
Verificationonpage100.
l
Ifthenameplateratedvoltageispresent,proceedtoStep3
l
Ifthevoltageis(+/-10%)outsideofthenameplateratedvoltage,restorecorrectvoltage
3. Verifyallthreephasesofvoltageafterthemainsfuses.
l
IfthenameplateratedvoltageispresentproceedtoStep4
l
Ifanyofthethreephasesarenotpresent,isolatecompressorpowerthenreplacethefuses
4. IsolatethecompressorpowerasdescribedintheSection1.8ElectricalIsolationonpage22.
5. Inspectallelectronicsforvisibledamage.
l
Ifnovisibledamageispresent,proceedtoStep6
l
Ifthereisanytypeofvisibledamage,replacethedamagedcomponent(s)
6. VerifyalloftheSoftStartfuses(ClosedToponly).RefertoSection4.14.2.2VerifyingSoftStartFuseson
page116.
l
Ifallofthefusesareokay,proceedtoStep7
l
Ifanyofthefusesareblown,replacethefuse(s)andreviewthecauseoftheblownfuses-Referto
Section5.5.2.6DeterminingtheCauseofBlownSoftStartFuses(Closed-TopSoftStartOnly)on
page272.
7. VerifytheInvertercabletotheInverterconnectorisinstalledcorrectly.
8. VerifytheDC-DCConverterresistances.RefertoSection4.24.2DC-DCConverterVerificationonpage
204.
l
IfDC-DCConverterresistancesarecorrect,proceedtoStep9
l
IfDC-DCConverterresistancesarenotcorrect,replacetheDC-DCConverterthenverifythePWM
andbearings
9. InstalltheDCBustestharness.RefertoSection1.10.1GeneralVerificationandInstallationoftheDC
BusTestHarnessonpage26.
10. DisconnecttheJ2(250VDC)andJ3(24VDC)(PottedDC-DC)orJ4(24VDC)OpenFrameDC-DC)outputs
fromtheDC-DCConverter.
11. InstalltheTopCoverthenre-applythecompressorpower.
M-SV-001-EN Rev. H-1/23/2023 Page 269 of 294

Table of Contents

Other manuals for Danfoss TTS300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss TTS300 and is the answer not in the manual?

Danfoss TTS300 Specifications

General IconGeneral
BrandDanfoss
ModelTTS300
CategoryAir Compressor
LanguageEnglish

Related product manuals