Component Test Point Expected Value Verification Section
Measured
Value
Fuses
F4&F5 30-38Ω 4.14.2.2VerifyingSoftStart
Fuses
SolenoidActuators 4.8W 108Ω–132Ω 4.6.3SolenoidVerification
9.3W 56.25Ω–68.75Ω 4.6.3SolenoidVerification
StatorResistance Phase1:2 >0.0Ωand<1Ω 4.23.4.2StatorResistance
Verification
Phase1:3 >0.0Ωand<1Ω 4.23.4.2StatorResistance
Verification
Phase2:3 >0.0Ωand<1Ω 4.23.4.2StatorResistance
Verification
StatorThermistor
Resistance
+to- 150-300Ωat70°
F(21°C)
4.23.4.2StatorResistance
Verification
M-SV-001-EN Rev. H-1/23/2023 Page 289 of 294