48 
 
ROW OFFSET 
Shifts the vertical start of print position (0 - 99.99 inches) on the label, where: 
00.00 inches  Is the Default Setting. 
 
COLUMN 
OFFSET 
Shifts the HORIZONTAL, left-justified start of print position to the right (0-99.99 
inches), without shifting the LABEL WIDTH termination point to the right, where:  
00.00 inches  Is the Default Setting. 
 
PRESENT 
DISTANCE 
Sets the label stop position (0 - 4.00 inches) past the start of print position upon 
output. When subsequent label formats are received, the printer will automatically 
back up the label to position it at the start of print position, where:  
00.00 inches  Is the Default Setting. (Auto Mode) 
 
Notes: 
(1) When set to zero (0), the printer assumes "Auto Sense Mode" to automatically configure 
the positioning requirements of an attached device (i.e., tear bar, cutter, peel & present 
mechanism, or present sensor).  
 
(2) When set to a value of 0.01 "Auto Sense Mode" is disabled, but the printer retains a 
zero (0) positioning value. 
 
CUSTOM 
ADJUSTMENTS 
Change the factory adjustment parameters (listed below) to finely and 
independently tune the printer to compensate for slight mechanical differences 
sometimes evident if multiple printers share label formats, or to make special label 
formatting adjustments, where:  
DARKNESS 
Controls the strobe time (1 - 64) to establish the nominal HEAT setting for 
printhead-specific thermal characteristics, where:   
32  Is the Default Setting. 
CONTRAST 
Allows fine-tuning (1 - 64) of the relative print edge (gray) adjustment for print 
quality, where:  
32  Is the Default Setting. 
ROW ADJUST 
Shifts the vertical start of print position (-100 - 100 dots) to fine-tune the ROW 
OFFSET setting, where:  
000  Is the Default Setting. (Note that if shifting Row Adjust in the negative direction, 
modify the PRESENT ADJUST setting [see below] by the same amount.) 
COLUMN 
ADJUST 
Shifts both the horizontal start of print position and the LABEL WIDTH termination 
point to the right (0-128 dots) to fine-tune the COLUMN OFFSET setting, where: 
000  Is the Default Setting. 
PRESENT 
ADJUST 
Adjusts the label stopping position (0 - 128 dots) to fine-tune the PRESENT 
DISTANCE setting, where: 
64  Is the Default Setting.