68
PARITY
Sets word parity, where:
NONE Parity is not used. (Default Setting)
ODD Odd parity is used.
EVEN Even parity is used.
DATA BITS
Sets word length, where:
7 A seven bit word is used.
8 An eight bit word is used. (Default Setting)
STOP BITS
Sets the number of stop bits, where:
1 One stop bit is used. (Default Setting)
2 Two stop bits are used.
PARALLEL PORT A
Controls the communication setting for the parallel port, where:
PORT DIRECTION
Determines if data is returned from the printer:
UNI-DIRECTIONAL No data is sent from the printer; the communication is one-way.
BI-DIRECTIONAL Data is sent from the printer in compliance with IEEE 1284 back-
channel operation. (Default Setting)
Note:
An IEEE 1284 bidirectional cable must be used when this
mode is selected.
NIC ADAPTER
Controls the communications settings for the network interface, as
follows:
IP ADDRESS
Specifies the static IP Address of the interface in the standard dotted-
decimal format, for example: 010.001.001.130.
SUBNET MASK
Specifies the static Subnet assigned to the interface, for example:
255.255.255.000.
GATEWAY
Specifies the Gateway Address the interface will use, for example:
010.001.001.001.
SNMPTRAP
DESTINATION
Specifies the network IP Address where SNMP traps will be sent when
SNMP service is installed on your receiver. If zeroed, no traps are sent.