70
ESC
SEQUENCES
Allows data containing invalid ESC control code sequences to be
processed, where:
ENABLED Normal command processing occurs. (Default Setting)
DISABLED ESC sequences are ignored during data processing (since some systems
send a “banner” to the printer). Bitmapped font downloads are disabled in
this mode.
HEAT
COMMAND
Determines the way the DPL Heat Command is handled, where:
ENABLED Normal command processing occurs. (Default Setting)
DISABLED Heat commands are ignored; instead, the heat value is controlled via the
menu setting.
SPEED
COMMANDS
Determines the way DPL Print, Feed, Slew, and Reverse commands are
handled, where:
ENABLED Normal command processing occurs. (Default Setting)
DISABLED Print, Feed, Slew, and Reverse commands are ignored; instead, the
speeds are controlled via the menu setting.
TOF SENSING
COMMANDS
Determines the way in which DPL Gap, Continuous, and Reflective
commands are handled, where:
ENABLED Normal command processing occurs. (Default Setting)
DISABLED Gap, Continuous, and Reflective commands are ignored; instead, the
sensing method is controlled via the menu setting.
SYMBOL SET
COMMAND
Determines the way in which DPL Single and Double Symbol Set
commands are handled, where:
ENABLED Normal command processing occurs. (Default Setting)
DISABLED Symbol Set commands are ignored; instead, the symbol set selection is
controlled via the menu setting.
CNTRL-CODES
(DATA)
Determines the way in which DPL SOH, STX, CR, ESC, and ^ codes are
handled, where:
ENABLED Normal command processing occurs. (Default Setting)
DISABLED Control Code functions are ignored; instead, the control code functions
are established via the menu setting.
STX-V SW
SETTINGS
Determines the way in which the DPL <STX>V command is handled,
where:
ENABLED Normal command processing occurs. (Default Setting)
DISABLED The option-enable command is ignored; instead, the option selections are
controlled via the menu setting.
MAX LENGTH
COMMAND
Determines the way in which the DPL <STX>M command is handled,
where:
ENABLED Normal command processing occurs. (Default Setting)
DISABLED The maximum label length command is ignored; instead the maximum
label length is controlled via the menu setting.