70 
 
ESC 
SEQUENCES  
Allows data containing invalid ESC control code sequences to be 
processed, where:  
ENABLED  Normal command processing occurs. (Default Setting) 
DISABLED  ESC sequences are ignored during data processing (since some systems 
send a “banner” to the printer). Bitmapped font downloads are disabled in 
this mode. 
HEAT 
COMMAND 
Determines the way the DPL Heat Command is handled, where:   
ENABLED  Normal command processing occurs. (Default Setting) 
DISABLED  Heat commands are ignored; instead, the heat value is controlled via the 
menu setting.  
SPEED 
COMMANDS 
Determines the way DPL Print, Feed, Slew, and Reverse commands are 
handled, where:  
ENABLED  Normal command processing occurs. (Default Setting) 
DISABLED  Print, Feed, Slew, and Reverse commands are ignored; instead, the 
speeds are controlled via the menu setting.  
TOF SENSING 
COMMANDS 
Determines the way in which DPL Gap, Continuous, and Reflective 
commands are handled, where:  
ENABLED  Normal command processing occurs. (Default Setting) 
DISABLED  Gap, Continuous, and Reflective commands are ignored; instead, the 
sensing method is controlled via the menu setting.  
SYMBOL SET 
COMMAND 
Determines the way in which DPL Single and Double Symbol Set 
commands are handled, where:  
ENABLED  Normal command processing occurs. (Default Setting) 
DISABLED  Symbol Set commands are ignored; instead, the symbol set selection is 
controlled via the menu setting.   
CNTRL-CODES 
(DATA) 
Determines the way in which DPL SOH, STX, CR, ESC, and ^ codes are 
handled, where:  
ENABLED  Normal command processing occurs. (Default Setting) 
DISABLED  Control Code functions are ignored; instead, the control code functions 
are established via the menu setting.    
STX-V SW 
SETTINGS 
Determines the way in which the DPL <STX>V command is handled, 
where:   
ENABLED  Normal command processing occurs. (Default Setting) 
DISABLED  The option-enable command is ignored; instead, the option selections are 
controlled via the menu setting.  
MAX LENGTH 
COMMAND 
Determines the way in which the DPL <STX>M command is handled, 
where:   
ENABLED  Normal command processing occurs. (Default Setting) 
DISABLED  The maximum label length command is ignored; instead the maximum 
label length is controlled via the menu setting.