61
I-Class Mark II Maintenance Manual
Removal and Replacement
Replacement:
1. Position the Power Supply PCB in the printer then secure it with the four Screws.
2. Place the Washer onto the Screw, and then secure the Ground Wire Lug to the chassis with the Screw.
3. Position the Nut Plate over the AC Connector and then secure the AC Connector and the Nut Plate to the
chassis with the two Screws.
4. Reconnect the cables to the Power Supply PCB.
5. Verify the correct Printhead supply voltage; see Section 2.2.4.