57
I-Class Mark II Maintenance Manual
Removal and Replacement
4.8 Media Sensor
Removal:
1. Turn OFF and unplug the printer.
2. Remove the Cover Assembly; see Section 4.1.
3. Disconnect the Media Sensor cable and remove the Screw that secures the Media Sensor Guide to the
Post.
4. Pull the Media Sensor Guide and then the Media Sensor from the printer.
Replacement:
1. Reinstall the Media Sensor and then the Media Sensor Guide.
2. Secure the Media Sensor Guide to the Post with the Screw.