1240 | Router Information Protocol (RIP)
www.dell.com | support.dell.com
Parameters
Defaults
Not configured.
Command Modes
ROUTER RIP
Command
History
Related
Commands
distribute-list out
c e s
Configure a filter for outgoing routing updates.
Syntax
distribute-list prefix-list-name out [interface | bgp | connected | isis | ospf | static]
To delete the filter, use the no distribute-list prefix-list-name out command.
Parameters
prefix-list-name
Enter the name of a configured prefix list.
interface
(OPTIONAL) Identifies the interface type slot/port as one of the following:
For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet
followed by the slot/port information.
For a Port Channel interface, enter the keyword
port-channel followed by a
number:
C-Series and S-Series Range: 1-128
E-Series Range: 1 to 32 for EtherScale, 1 to 255 for TeraScale and 1 to 512 for
ExaScale.
For a SONET interface, enter the keyword
sonet followed by the slot/port
information.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet
followed by the slot/port information.
For a VLAN, enter the keyword
vlan followed by a number from 1 to 4094.
Version 7.8.1.0 Introduced on S-Series
Version 7.6.1.0 Introduced on C-Series
pre-Version 6.2.1.1 Introduced on E-Series
ip prefix-list Enter the PREFIX-LIST mode and configure a prefix list.
prefix-list-name
Enter the name of a configured prefix list.
interface
(OPTIONAL) Identifies the interface type slot/port as one of the following:
For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet
followed by the slot/port information.
For a Port Channel interface, enter the keyword
port-channel followed by a
number:
C-Series and S-Series Range: 1-128
E-Series Range: 1 to 32 for EtherScale, 1 to 255 for TeraScale and 1 to 512 for
ExaScale.
For a SONET interface, enter the keyword
sonet followed by the slot/port
information.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet
followed by the slot/port information.
For a VLAN, enter the keyword
vlan followed by a number from 1 to 4094.
connected (OPTIONAL) Enter the keyword connected to filter only directly connected
routes.

Table of Contents