EasyManua.ls Logo

Dell Force10 TeraScale E Series - Far-End Failure Detection (FEFD); Overview; Commands

Dell Force10 TeraScale E Series
1640 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Far-End Failure Detection (FEFD) | 479
17
Far-End Failure Detection (FEFD)
Overview
FTOS supports Far-End Failure Detection (FEFD) on the Ethernet interfaces of the E-Series, as
indicated by the e character that appears below each command heading. This feature detects and
reports far-end link failures.
FEFD is not supported on the Management interface.
During an RPM failover, FEFD is operationally disabled for approximately 8-10 seconds.
By default, FEFD is disabled.
Commands
The FEFD commands are:
debug fefd
fefd
fefd mode
fefd-global
fefd disable
fefd interval
fefd-global interval
fefd reset
show fefd
debug fefd
e
Enable debugging of FEFD.
Syntax
debug fefd {events | packets} [interface]
To disable debugging of FEFD, use the no debug fefd {events | packets} [interface] command.
Parameters
events Enter the keyword events to enable debugging of FEFD state changes.

Table of Contents