Loading...
146 | Control and Monitoring
www.dell.com | support.dell.com
Example
Figure 5-56. Command Example: show switch links backplane
show system (S-Series)
s
Display the current status of all stack members or a specific member.
Syntax
show system [brief | stack-unit unit-id]
Parameters
Command Modes
EXEC
EXEC Privilege
Command
History
Usage
Figure 5-57
shows the output from the show system brief command.
Figure 5-58 shows the output from the show system stack-unit command.
FTOS# show switch links backplane
Switch fabric backplane link status:
SFM0 Links Status SFM1 Links Status
LC SlotID Port0 | Port1 | Port2 | Port3 | Port4 | Port5 | Port6 |
Port7
0 up up up up down down down down
1 not present
2 not present
3 not present
4 not present
5 not present
6 up up up up down down down down
7 not present
up - Both ends of the link are up
down - Both ends of the link are down
up / down - SFM side up and LC side down
down / up - SFM side down and LC side up
FTOS#
brief (OPTIONAL) Enter the keyword brief to view an abbreviated list of system
information.
stack-unit unit-id (OPTIONAL) Enter the keyword stack-unit followed by the stack member ID for
information on that stack member. Range: 0 to 7.
Version 7.8.1.0 Modified output: Boot Flash field will display code level for boot code 2.8.1.1 and newer,
while older boot codes are displayed as "Present".
Version 7.7.1.0 Modified output: Added Master Priority field.
Version 7.6.1.0 Introduced for S-Series switches

Table of Contents