1532 | C-Series Diagnostics and Debugging
www.dell.com | support.dell.com
show buffer-profile
c s
Display the buffer profile that is applied to an interface.
Syntax
show buffer-profile {detail | summary} {csf | fp-uplink}
Parameters
Defaults
None
Command Mode
INTERFACE
Command
History
Example
Figure 64-19. show buffer-profile Command Example
Related
Commands
show buffer-profile interface
c s
Display the buffer profile that is applied to an interface.
Syntax
show buffer-profile {detail | summary} interface interface slot/port
Parameters
Defaults
None
Command Mode
INTERFACE
detail
Display the buffer allocations of the applied buffer profiles.
summary
Display the buffer-profiles that are applied to line card port-pipes in the
system.
csf
Display the Switch Fabric Processor buffer profiles that you have applied to
line card port-pipes in the system.
fp-uplink
Display the Field Processor buffer profiles that you have applied to line card
port-pipes in the system.
Version 7.7.1.0 Introduced on S-Series
Version 7.6.1.0 Introduced on C-Series
FTOS#show buffer-profile summary fp-uplink
Linecard Port-set Buffer-profile
0 0 test1
4 0 test2
FTOS#
buffer-profile (Configuration)
Create a buffer profile that can be applied to an interface.
detail
Display the buffer allocations of a buffer profile.
summary
Display the Field Processors and Switch Fabric Processors that are applied
to line card port-pipes in the system.
interface interface
Enter the keyword interface followed by the interface type, either
gigabitethernet or tengigabitethernet.
slot/port
Enter the slot and port number of the interface.