228 | Access Control Lists (ACL)
www.dell.com | support.dell.com
Defaults
Not configured.
Command Modes
CONFIGURATION-EXTENDED-ACCESS-LIST 
Command
History
Usage
Information
The order option is relevant in the context of the Policy QoS feature only. See the “Quality of 
Service” chapter of the FTOS Configuration Guide for more information.
When you use the log option, CP processor logs details about the packets that match. Depending on 
how many packets match the log entry and at what rate, the CP may become busy as it has to log these 
packets’ details.
The C-Series and S-Series cannot count both packets and bytes, so when you enter the count byte 
options, only bytes are incremented.
The monitor option is relevant in the context of flow-based monitoring only. See Chapter 44, Port 
Monitoring.
Most ACL rules require one entry in the CAM. However, rules with TCP and UDP port operators (gt, 
lt, range) may require more than one entry. The range of ports is configured in the CAM based on bit 
mask boundaries; the space required depends on exactly what ports are included in the range. 
monitor (OPTIONAL) Enter the keyword monitor when the rule is describing the 
traffic that you want to monitor and the ACL in which you are creating the rule 
will be applied to the monitored interface. For details, see the section 
“Flow-based Monitoring” in the Port Monitoring chapter of the FTOS 
Configuration Guide.
fragments Enter the keyword fragments to use ACLs to control packet fragments.
Version 8.3.1.0
Added 
dscp keyword.
Version 8.2.1.0 Allows ACL control of fragmented packets for IP (Layer 3) ACLs.
Version 8.1.1.0 Introduced on E-Series ExaScale
Version 7.6.1.0 Added support for S-Series
Version 7.5.1.0 Added support for C-Series
Version 7.4.1.0
Added support for non-contiguous mask and added the 
monitor option. Deprecated 
established keyword.
Version 6.5.10
Expanded to include the optional QoS 
order priority for the ACL entry.
Note: When ACL logging and byte counters are configured simultaneously, byte counters 
may display an incorrect value. Configure packet counters with logging instead.