916 | Multicast Listener Discovery (MLD)
www.dell.com | support.dell.com
Parameters
Defaults
No default values or behavior
Command Modes
EXEC Privilege
Command
History
Related
Commands
debug ipv6 mld
e
Enable debugging on IPv6 MLD packets.
Syntax
debug ipv6 mld {group-address | interface}
To turn off debugging, use the no debug ipv6 mld {group-address | interface} command.
Parameters
Defaults
Disabled
Command Modes
EXEC Privilege
interface
(OPTIONAL) Enter the following keywords and slot/port or number
information:
For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet
followed by the slot/port information.
For a Port Channel interface, enter the keyword
port-channel followed by
a number:
E-Series Range: 1 to 32 for EtherScale, 1 to 255 for TeraScale and 1 to 512
for ExaScale.
For a SONET interface, enter the keyword
sonet followed by the slot/port
information.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet followed by the slot/port information.
For a VLAN, enter the keyword
vlan followed by a number from 1 to 4094.
group-address (OPTIONAL) Enter the group address in the x:x:x:x::x format.
The
:: notation specifies successive hexadecimal fields of zero.
Version 7.4.1.0 Introduced
show ipv6 mld interface Display the IPv6 MLD interface
group-address (OPTIONAL) Enter the multicast group address in the x:x:x:x::x format.
The
:: notation specifies successive hexadecimal fields of zero.
interface
(OPTIONAL) Enter the following keywords and slot/port or number information:
For a 1-Gigabit Ethernet interface, enter the keyword
GigabitEthernet followed
by the slot/port information.
For a Port Channel interface, enter the keyword
port-channel followed by a
number:
E-Series Range: 1 to 32 for EtherScale, 1 to 255 for TeraScale and 1 to 512 for
ExaScale.
For a SONET interface, enter the keyword
sonet followed by the slot/port
information.
For a 10-Gigabit Ethernet interface, enter the keyword
TenGigabitEthernet
followed by the slot/port information.
For a VLAN, enter the keyword
vlan followed by a number from 1 to 4094.

Table of Contents