NOTE: Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 56. Connector descriptions for 4 x 3.5 inch SATA with BOSS N1 (optional)
Order From To
1 SL1_PCH_SA1 (system board signal
connector)
BP_DST_SA1 (backplane signal
connector)
2 PIB (system board connector) PIB_SIG_1 (PIB signal connector)
3 P1 (system board power connector) SYS (PIB power connector)
4 P2 (system board power connector) CPU (PIB power connector)
5 SIG_PWR_1(PIB power connector) BP_PWR_1 (backplane power
connector)
6 CTRL_PNL (system board control panel
connector)
Right Ear
7 LEFT_LED (system board control panel
connector)
Left Ear
8 R_INTRUSION (system board intrusion
switch connector)
Intrusion switch
9 SL2_PCH_PA2 (system board signal
connector)
J_PCIE_1 (BOSS N1 signal connector)
10 MB_BOSS_PWR (System board power
connector)
J_PWR_1 (BOSS N1 power connector)
Figure 29. Configuration 1: 4 x 3.5 inch SAS/SATA and fPERC with BOSS N1 (optional)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 57. Connector descriptions for 4 x 3.5 inch SAS/SATA and fPERC with BOSS N1 (optional)
Order From To
1 J_SLOT1 (fPERC Riser) CTRL_DST_PA1 (fPERC connector)
Installing and removing system components 63