Table 57. Connector descriptions for 4 x 3.5 inch SAS/SATA and fPERC with BOSS N1
(optional)(continued)
Order From To
2 PIB (system board connector) PIB_SIG_1 (PIB signal connector)
3 P1 (system board power connector) SYS (PIB power connector)
4 P2 (system board power connector) CPU (PIB power connector)
5 SIG_PWR_1(PIB power connector) BP_PWR_1 (backplane power
connector)
6 SL2_PCH_PA2 (system board signal
connector)
J_PCIE_1 (BOSS N1 signal connector)
7 MB_BOSS_PWR (System board power
connector)
J_PWR_1 (BOSS N1 power connector)
Figure 30. Configuration 2: 4 x 3.5 inch SAS/SATA and internal PERC card
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 58. Connector descriptions for 4 x 3.5 inch SAS/SATA and internal PERC card
Order From To
1 CTRL_SRC_SA1 (adapter PERC
controller connector)
BP_DST_SA1 (backplane signal
connector)
2 PIB (system board connector) PIB_SIG_1 (PIB signal connector)
3 P1 (system board power connector) SYS (PIB power connector)
4 P2 (system board power connector) CPU (PIB power connector)
5 SIG_PWR_1(PIB power connector) BP_PWR_1 (backplane power
connector)