Figure 77. Configuration 4-6: 10 x 2.5-inch SAS4/SATA RAID with Rear 2 x 2.5-inch (with FPERC12)
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 79. 10 x 2.5-inch SAS4/SATA RAID with Rear 2 x 2.5-inch (with FPERC12)
Order From To
1 SIG_PWR_1 (system board power connector) BP_PWR_1 (backplane power connector)
2 MB_SIG_PWR_0 (system board power connector) R_BP_PWR_1 (rear backplane power connector)
3 SL1 (signal connector on system board) CTRL_DST_PA1 (front PERC)
4 SL3 (signal connector on system board) CTRL_DST_PB1 (front PERC)
5 CTRL_SRC_SB1 (front PERC) BP_DST_SB1 (backplane signal connector) &
R_BP_DST_SA1 (rear backplane)
6 CTRL_SRC_SA1_PA1 (front PERC) BP_DST_SA1 (backplane signal connector)
Installing and removing system components 105