Script Commands 231
NOTE: When all firmware downloads have successfully completed, this command
returns a
Successful status. If any firmware downloads fail, this command shows
the firmware download status of each targeted physical disk. This command returns
the status values shown in the following table.
Show RAID Controller Module
For each RAID controller module in a storage array, this command returns the
following information:
• Status (Online, Offline)
• Current firmware and NVSRAM configuration
• Pending firmware and NVSRAM configuration configurations (if any)
•Board ID
•Product ID
• Product revision
• Serial number
• Date of manufacture
• Date and time to which the RAID controller module is set
• Associated virtual disks (including preferred owner)
• Ethernet port
• Physical disk interface
Syntax
show (allControllers | controller [(0 | 1)])
[summary]
Status Definition
Successful Downloads completed without errors.
Not Attempted Downloads did not start.
Partial Download Downloads are in progress.
Failed Downloads completed with errors.
book.book Page 231 Friday, March 4, 2011 10:45 AM