Chapter 6 Control Modes of Operation ASDA-B2
6-18 Revision September 2013
actual condition.
Analog Speed Command Low-pass Filter
Analog Speed Command Low-pass Filter is used to eliminate high frequency response
and electrical interference from an analog speed command and it is also with
smoothing function.
Relevant parameters:
P1-06 SFLT
Accel / Decel Smooth Constant of Analog
Speed Command (Low-pass Filter)
Address: 010CH
010DH
Operation
Interface:
Keypad/Software Communication
Related Section:
Section 6.3.3
Default: 0
Control
Mode:
S
Unit: ms
Range: 0 ~ 1000 (0: Disabled)
Data Size: 16-bit
Display
Format:
Decimal
Settings: 0: Disabled
NOTE
1) If the setting value of parameter P1-06 is set to 0, it indicates the function of this
parameter is disabled and the command is just By-Pass.
SFLT
Target Speed
VARITEL INGENIERIA ELECTRONICA S.A.
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics ASDA-B2 series and is the answer not in the manual?

Delta Electronics ASDA-B2 series Specifications

General IconGeneral
BrandDelta Electronics
ModelASDA-B2 series
CategoryServo Drives
LanguageEnglish

Related product manuals