ASDA-B2 Chapter 6 Control Modes of Operation
Revision September 2013 6-37
6.4.3 Smoothing Strategy of Torque Control Mode
Relevant parameters:
P1-07 TFLT
Smooth Constant of Analog Torque
Command (Low-pass Filter)
Address: 010EH
010FH
Operation
Interface:
Keypad/Software Communication
Related Section:
Section 6.4.3
Default: 0
Control
Mode:
T
Unit: ms
Range: 0 ~ 1000 (0: Disabled)
Data Size: 16-bit
Display
Format:
Decimal
Settings: 0: Disabled
NOTE
1) If the setting value of parameter P1-07 is set to 0, it indicates the function of this
parameter is disabled and the command is just By-Pass.
TFLT
Target Speed
VARITEL INGENIERIA ELECTRONICA S.A.
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.