ASDA-B2 Chapter 7 Servo Parameters
Revision September 2013 7-11
007: Overspeed
008: Abnormal pulse control command
009: Excessive deviation
010: Reserved
011: Encoder error (The wiring of the encoder is in error and this causes the
communication error between the servo drive and the encoder.)
012: Adjustment error
013: Emergency stop activated
014: Reverse limit switch error
015: Forward limit switch error
016: IGBT temperature error
017: Memory error
018: Encoder output error
019: Serial communication error
020: Serial communication time out
021: Reserved
022: Input power phase loss
023: Pre-overload warning
024: Encoder initial magnetic field error
025: Encoder internal error
026: Encoder data error
027: Motor internal error
028: Motor internal error
029: Motor internal error
030: Motor protection error
030: Motor protection error
031: U,V,W, GND wiring error
035: Motor temperature error
048: Excessive encoder output error
067: Motor temperature warning
099: DSP firmware upgrade
P0-02 STS Drive Status (Front Panel Display)
Address: 0004H
0005H
Operation
Interface:
Keypad/Software Communication
Related Section:
Section 7.2
Default: 00
Control
Mode:
ALL
Unit: -
Range: 0 ~ 18
Data Size: 16-bit
Display
Format:
Decimal
VARITEL INGENIERIA ELECTRONICA S.A.
info@varitel.com - www.varitel.com - Tel. (54) 11-4243-1171 / Fax: (54) 11-4292-7545
Manuel Baliña 456, Lomas de Zamora (B1832CCJ) Buenos Aires, Argentina.