ASDA-B2 Chapter 2 Installation and Storage
Revision September 2013 2-13
Allowable Frequencies for Servo Motor Running Without Load (times/min)
When Using External Regenerative Resistor
Motor Capacity
Regenerative Resistor
ECMA□□E
0.5kW 1kW 1.5kW 2.0kW 2.0kW 3.0kW
05 1.0 15 20 20 30
200W 80Ω 149 144 109 83 35 22
400W 40Ω - 289 217 166 70 44
1kW 30Ω - - - 416 175 110
Allowable Frequencies for Servo Motor Running Without Load (times/min)
When Using External Regenerative Resistor
Motor Capacity
Regenerative Resistor
ECMA□□G
0.3kW 0.6kW 0.9kW
03 06 09
200W 80Ω 149 144 109
400W 40Ω - - 217
When the regenerative resistor capacity is not enough, the users can connect to
multiple the same capacity regenerative resistors in parallel to increase it.
Dimensions
Delta Part Number : BR400W040 (400W 40Ω)
L1 L2 H D W MAX. WEIGHT(g)
265 250 30 5.3 60 930