6159932010-09
23 / 60
English
CVIC - MODCVIC - MULTICVIC
Err.Ack. Yes/No (to validate start cycle after a reject report).
Push Start (no by default). When this function is enabled (yes), the tool «Push Start» is inhibited. The tool is
started either by pressing the lever or enabling the external start input.
Ergo-stop When this function is enabled, the operator will experience less of a jerk at the at the end of the
tightening operation.
RP durat A value which is different from 0 allows you to program the pulse (0.1 to 4.0 s) reports (accept, reject)
at end of cycle.
With a value equal to 0, you can have a constant «0» or «1» status of report.
Fc(Hz) Bandwidth adjustment from 4 to 128 Hz. Reducing this value allows you to filter the defects in the
«torque» signal and improve the dispersion of the torque installed (Cp or Cam), which may be useful
in particular when using a «Crowfoot» head. Warning: as a result, the adjustment of the torque (Cpk)
may be modified. It can be adjusted by calibrating the tool on the assembly (see Manual Calibration
Section in the Maintenance menu).
2.5 - «PC LINK» Menu
Menu: MAIN\PARAMETERS\PC LINK.
2.5.1 - CVIC
The parameters used for downloading to the PC are as follows:
RS232/RS422:
RS232 default standard type used for connecting a PC and a single controller
RS422 used in a network configuration only.
Baud rate from 300 to 19,200 Bauds, 7 or 8 data bits, 1 or 2 stop bits, no parity/even/odd.
Default values: 19,200 Bauds, 8 data bits, 1 stop bit, no parity.
Slave # 0-254. In a network configuration, the PC is connected to several controllers at the same
time.
For further information about the network connection, refer to the «CVIPC» Operator’s
Manual.
2.5.2 – MODCVIC
For the MODCVIC module, the switching of the communications standard RS232 / RS422 is automatic
depending on the address selected by the rotary switches:
- address 0 implies standard RS232 for the connection of a PC and a single controller.
- any other address selected implies standard RS422 for a network connection.
The other parameters are set to:
- 19,200 bauds.
- 8 data bits.
- 1 stop bit.
- no parity.
They cannot be programmed by the PC.
In the case of a network connection, the «Intermediate» or «end of line» differentiation is obtained by resistance
wiring in the connectors of the network cable (see wiring diagrams).