User Manual DEV 2190
76 Copyright DEV Systemtechnik GmbH 2009-2017
5.5.4.3.7.2 .application.switchUnitTable.switchUnitEntry.swSize
OID: .1.3.6.1.4.1.21035.41.2.7.1.2.x
Syntax: INTEGER32
Access: read-only
Description: The size of the switch unit (here: redundancy unit).
Due to the 2:1 redundancy switch applied with a redundant ampli-
fier option, "2" is returned.
5.5.4.3.7.3 .application.switchUnitTable.switchUnitEntry.swMembers
OID: .1.3.6.1.4.1.21035.41.2.7.1.3.x
Syntax: OCTET STRING
Access: read-only
Description: A comma separated string that is interpreted as integers, con-
taining the indices of the ports in the .portTable (please refer to
chapter 5.5.4.3.9) being member of the switch unit (here: redun-
dancy unit).
Example: first redundancy unit: "1,2,", second redundancy unit: "3,4," (…)
5.5.4.3.7.4 .application.switchUnitTable.switchUnitEntry.swPosition
OID: .1.3.6.1.4.1.21035.41.2.7.1.4.x
Syntax: INTEGER32
Access: read-write
Description: The switching status of the corresponding switch unit (here: redun-
dancy unit). By writing to .swPosition the switching state can be
altered; possible values:
"1" the unit is (to be) switched to the main channel;
"2" the unit is (to be) switched to the backup channel.
Note:
.swPosition is used to perform the switching via SNMP in Remote Mode.
5.5.4.3.8 .application.numberOfPorts
OID: .1.3.6.1.4.1.21035.41.2.8.0
Syntax: INTEGER32 (0..255)
Access: read-only
Description: The number of ports with special properties within the device.
Each amplifier module is considered as a single port.
Example: "4" for a device with 4 amplifier modules
Note:
This value determines the maximum index of the following table: