User Manual DEV 2190
Copyright DEV Systemtechnik GmbH 2009-2017 81
5.5.4.3.9.17 .application.portTable.portEntry.poSlot
OID: .1.3.6.1.4.1.21035.41.2.9.1.17.x
Syntax: OCTET STRING (SIZE(32))
Access: read-only
Description: The slot location of the module to which the port belongs to.
As explained in chapter 5.4.4, the slots on the front side of the
device are counted from left to right (i.e. 1…16), but only slots are
considered in counting which are populated with amplifier
modules. Other modules (i.e. redundancy switch modules), and
empty slots (if not reserved for the use with amplifier modules) are
not considered.
Example: If a DEV 2190 is equipped with amplifier modules as in the example
of chapter 3.3.5, one of the following strings is returned for .poSlot:
• "Amp1" for the amplifier module in the first slot
• "Amp2" for the amplifier module in the third slot
• "Amp3" for the amplifier module in the fourth slot
• "Amp4" for the amplifier module in the sixth slot
• "Amp5" for the amplifier module in the seventh slot
• "Amp6" for the amplifier module in the eighth slot
• "Amp7" for the amplifier module in the ninth slot
E.g. if the eighth slot becomes reserved (i.e. if the module is
removed and after a device reset), the same values are returned
for .poSlot, except for the eighth slot, for this port an empty string
is returned.
5.5.4.3.9.18 .application.portTable.portEntry.poRfSenseStatus
OID: .1.3.6.1.4.1.21035.41.2.9.1.18.x
Syntax: INTEGER {(0), ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The status of the RF level monitoring, possible values:
"0" is returned for an empty slot;
"1" ok: the RF level is above the RF threshold level;
"2" not ok: the RF level is below the RF threshold level;
"3" not applicable: is not returned for this type of device.
5.5.4.3.9.19 .application.portTable.portEntry.poBiasStatus
OID: .1.3.6.1.4.1.21035.41.2.9.1.19.x
Syntax: INTEGER {(0), ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The status of the LNB (bias) current monitoring, possible values:
"0" is returned for an empty slot;
"1" ok: the current is within the defined current monitoring
interval (or LNB power is turned off);
"2" not ok: the current exceeds the defined current monitoring
interval;
"3" not applicable: is not returned for this type of device.