User Manual DEV 2190
82 Copyright DEV Systemtechnik GmbH 2009-2017
5.5.4.3.9.20 .application.portTable.portEntry.poLightStatus
OID: .1.3.6.1.4.1.21035.41.2.9.1.20.x
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The light detection status.
For this type of device, "3" (notapplicable) is returned for all ports.
5.5.4.3.9.21 .application.portTable.portEntry.poCardStatus
OID: .1.3.6.1.4.1.21035.41.2.9.1.21.x
Syntax: INTEGER {ok (1), notok (2), notapplicable (3)}
Access: read-only
Description: The health status of the module to which the port belongs to,
possible values:
"1" ok: no errors are reported for the module;
"2" not ok: a module error was detected;
"3" not applicable: this value is returned for empty slots.
5.5.4.3.9.22 .application.portTable.portEntry.poGainMode
OID: .1.3.6.1.4.1.21035.41.2.9.1.22.x
Syntax: INTEGER {notapplicable (0), manual (1), auto (2), mute (3)}
Access: read-write
Description: For this type of device, the gain mode can be read only,
possible values:
"0" not applicable: this value is returned for empty slots;
"1" manual: this value is returned for all amplifier modules, since
they are all providing manual gain control
functionality.
Note:
The values "2" (auto) and "3" (mute) are not supported by this type of device.
5.5.4.3.9.23 .application.portTable.portEntry.poOutputPowerSetpoint
OID: .1.3.6.1.4.1.21035.41.2.9.1.23.x
Syntax: INTEGER32
Access: read-write
Description: The automatic gain control set point.
For this type of device, "9999" is returned for all ports.
5.5.4.3.9.24 .application.portTable.portEntry.poHasInputPower
OID: .1.3.6.1.4.1.21035.41.2.9.1.24.x
Syntax: INTEGER {yes (1), no (2)}
Access: read-only
Description: The indication whether input power measurement capability is
provided or not.
.poHasInputPower is not implemented for this type of device.