User Manual DEV 2190
80 Copyright DEV Systemtechnik GmbH 2009-2017
5.5.4.3.9.12 .application.portTable.portEntry.poHasGain
OID: .1.3.6.1.4.1.21035.41.2.9.1.12.x
Syntax: INTEGER {yes (1), no (2), (0)}
Access: read-only
Description: The indication whether gain control is provided or not.
For this type of device, "1" (yes) is returned for all amplifier
modules and "0" is returned for an empty slot.
5.5.4.3.9.13 .application.portTable.portEntry.poGain
OID: .1.3.6.1.4.1.21035.41.2.9.1.13.x
Syntax: INTEGER32
Access: read-write
Description: The gain control value in [dB/10].
"9999" means not available or not present.
Example: "50" ≡ +5.0 dB
Note:
The factory setting is stated in chapter 4.3.1.
5.5.4.3.9.14 .application.portTable.portEntry.poHasTilt
OID: .1.3.6.1.4.1.21035.41.2.9.1.14.x
Syntax: INTEGER {yes (1), no (2), (0)}
Access: read-only
Description: The indication whether slope (or tilt) control is provided or not.
Only for products with applied Option 25, "1" (yes) is returned;
otherwise "2" (no). For an empty slot, "0" is returned.
5.5.4.3.9.15 .application.portTable.portEntry.poTilt
OID: .1.3.6.1.4.1.21035.41.2.9.1.15.x
Syntax: INTEGER32
Access: read-write
Description: The slope (or tilt) setting in [dB/10].
"9999" means not available or not present.
Example: "20" ≡ +2.0 dB
Note:
The factory setting is stated in chapter 4.3.1.
5.5.4.3.9.16 .application.portTable.portEntry.poCardType
OID: .1.3.6.1.4.1.21035.41.2.9.1.16.x
Syntax: OCTET STRING (SIZE(32))
Access: read-only
Description: The DEV name for the module to which this port belongs to.
Examples: "11-0096" (for a DEV 11-0096 amplifier module) and
"11-????" (for an empty slot)