User Manual DEV 2190
78 Copyright DEV Systemtechnik GmbH 2009-2017
5.5.4.3.9.3 .application.portTable.portEntry.poType
OID: .1.3.6.1.4.1.21035.41.2.9.1.3.x
Syntax: INTEGER32 (0..255)
Access: read-only
Description: The functionality of the port, possible values:
"0" any module port in a 1:1 configuration;
"1" main channel of a 1+1 redundancy unit;
"2" backup channel of a 1+1 redundancy unit.
Note:
For devices without applied redundancy switching functionality, "0" is returned
for all ports. For an empty slot, "0" is returned as well.
5.5.4.3.9.4 .application.portTable.portEntry.poHasRfSense
OID: .1.3.6.1.4.1.21035.41.2.9.1.4.x
Syntax: INTEGER {yes (1), no (2)}
Access: read-only
Description: The indication whether RF level information is provided or not.
For this type of device, "1" (yes) is returned for all amplifier
modules and "0" is returned for an empty slot.
5.5.4.3.9.5 .application.portTable.portEntry.poRfSense
OID: .1.3.6.1.4.1.21035.41.2.9.1.5.x
Syntax: INTEGER32
Access: read-only
Description: The measured RF level in [dBm/10].
"9999" means not available or not present.
Example: "-129" ≡ -12.9 dBm
5.5.4.3.9.6 .application.portTable.portEntry.poRfLimit
OID: .1.3.6.1.4.1.21035.41.2.9.1.6.x
Syntax: INTEGER32
Access: read-write
Description: The RF threshold level in [dBm/10].
"9999" means not available or not present.
Note:
The factory setting is stated in chapter 4.3.1.
5.5.4.3.9.7 .application.portTable.portEntry.poHasBias
OID: .1.3.6.1.4.1.21035.41.2.9.1.7.x
Syntax: INTEGER {yes (1), no (2)}
Access: read-only
Description: The indication whether bias (i.e. LNB power) is provided or not.
For this type of device, "1" (yes) is returned for all amplifier
modules and "0" is returned for an empty slot.