OPERATOR'S MANUAL
INSTALLATION/ 13
Dj SEED MANAGER® SE PLANTER MONITOR
BENCHMARK Series® 11001-1218-200112 Rev A
INCORRECT
There can be no skips in the row inputs on a Material Flow Module. The following
shows the previous eight row module setup incorrectly:
Row
1
Row
2
Row
3
Row
5
Row
4
Row
6
Row
7
Row
8
Row
9
Row
11
Row
10
Row
12
RS-485 IN RS-485 OUT
Follow the same examples on all Material Flow Modules used in the system. When
correctly connected, row 1 sensor should be connected to the Row 1 input on b1. The
monitor will then number the sensors from 1 to n starting on b1, then b2, and so on.
Hopper level sensors can be connected to 12 Row Material Flow Modules. Hopper
sensors can be connected to either of the hopper inputs on a Material Flow Module.
The monitor will identify the number of hopper sensors connected to each Material
Flow Module and will number them from 1 to n starting with any sensors connected to
b1. If no sensors are connected to b1, the number starts from b2 and so on.. In the
event that two hopper sensors are connected to a given module, the sensor connected
to input 1 is numbered before the sensor connected to input 2. The following shows
an example configuration with hopper sensors connected and how they would be
identified by the console.
P1
b1 b2 b3 b4
InOutInOut In Out In Out
P2
Hop 1 Hop 2
Hop 3 Hop 4
Figure 6H
Incorrect Install
Figure 6I