Configurethedeviceusing theweb interface System Configuration
Digi Connect Family and ConnectPort TSFamily
109
n
Connect every: H hrsM mins: The interval (period) in hoursand minutesin which the Digi
device server attemptsa timed connection to the specified Remote Manager Server.
n
After boot, wait before first timed connection: When the Digi device server boots (starts
up), you may observea delay before the first timed connection is attempted. Choose oneof
the following optionson how to handle the delay:
l
Immediate: Attempt first timed connection immediately.
l
One Interval: Attempt the first timed connection after oneconfigured interval (period) has
elapsed.
l
Random Delay: Attempt the first timed connection after a random interval of time
between zero (immediate) and the configured interval (period). Choose this option when
you have a number of Digi device deployed in a singlelocation and you want to distribute
the first Remote Manager timed connection attempt for each Digi device over timewhen
power isrestored after an outage.
Advanced Remote Manager settings
Thedefault settings for Remote Manager remote management work for most situations. The
advanced settingsallow you to configure the idle timeout for the connection between the Remote
Manager-registered device and Remote Manager, and the keep-alive settingsof the variousinterfaces
(TCPand HTTPfor mobile and Ethernet network connections). You should only change the advanced
settings when the defaultsdo not properly work.
n
Connection Settings: These settingsconfigure theidle timeout for the connection between
the Remote Manager-registered device and Remote Manager.
l
Disconnect when the Remote Manager Connection isidle
Idle Timeout: Enablesor disables the idletimeout for the connection. When enabled, an
idle connection endsafter the amount of time specified in the Idle Timeout setting.
l
Authenticate to Remote Manager with a password
Password: These fieldsare only applicablewhen your Remote Manager account was
configured to expect a password from the Remote Manager-registered device. Typically,
you can set this option through Remote Manager, since you need to configure theRemote
Manager-registered device and Remote Manager identically.

Table of Contents

Other manuals for Digi Connect Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi Connect Series and is the answer not in the manual?

Digi Connect Series Specifications

General IconGeneral
CategoryNetwork Router
SeriesConnect
ManufacturerDigi
Cellular Technology4G LTE, 3G
Serial Ports1-2 (varies by model)
SecurityVPN, Firewall
ManagementWeb, CLI, SNMP

Related product manuals