Change Bank
When changing bank, all controllers congured in manual cue mode One for each bank, will control
the manual cue it has been assigned in the new bank. If a manual cue is active, it will stay active and
continue to give its contribution even by changing bank.
It is important to note that in such a situation, there is no control on the console capable of control-
ling the above-mentioned manual (except Release All); to regain control, it is necessary to change
the bank once again and return to the previous bank and then move the controller slider until cross-
ing the original value of the manual cue.
A controller congured in Manual cue, Fixed mode is not inuenced by the bank change and keeps
controlling the same manual cue.
2.3 GRAND MASTER AND GROUP MASTERS
You can intervene in real time on the result of the cue and manual cue elaboration using the Grand Mas-
ter (and DBO key) and group masters.
The Grand Master only inuences the HTP channels (typically the xtures dimmer) proportionally reduc-
ing their value.
The controllers can be congured as group masters (see Controllers paragraph); in this case, we could
have up to 12 intensity masters corresponding to as many groups..
A group master, just like a Grand Master, proportionally reduces all HTP channels of the xtures belong-
ing to the group itself.
IMPORTANT: if a xture belongs to more groups, the lowest master is considered.