49
PULSE MX
The IP number and the subnet mask are each composed of 4 octets ranging from 0 to 255, separated
by a full stop. A simplied rule to assign IP numbers to a network without a DHCP server is as follow:
all devices must have the same octets for the subnet mask 255, while the octets corresponding to the
0s in the subnet mask must form a unique combination for each device.
Artnet configuration
To congure Artnet, simply press the Enable button and set the Sub-Net and Universe values to the same
ones assigned to the Artnet receiver. These two values indicate the rst DMX Universe of the console.
The other 5 DMX Universes are sent through the same Sub-net and the following Universe.
Enable:
Enables/disables Artnet output.
Sub-Net:
Set a value between 0 and 15 accordingly to the receiver connected to the console.
Universe:
Set a value between 0 and 15 accordingly to the receiver connected to the console. This value consti-
tutes the rst of the six DMX Universes transmitted by the console, while the other 5 are sent through
consecutive Universe values.
Certain Artnet systems use the naming Net and Universe, whose validity range is respectively 0-127 and
0-255. In this case, Net must be set to 0, while Universe must equal 16 x SubNet) + Universe.
• The OK button saves all changes made and goes back to the Setup menu.
• The Cancel button goes back to the Setup menu without saving any change.