XF6 Series Installation and Programming Guide Digital Monitoring Products
25
Programming operation.
Cell APN
Enter the first APN (Access Point Name). This allows an access point for cellular
communication and is used to connect to a DNS network. The APN may contain two lines
of 16 characters to equal 32 characters. Default is set to SECURECOM400.
Entré Connection
This option displays if the panel has network or cellular capability. Select NET to allow a
dedicated network connection with Entré. Options are NONE or NET. Default is NONE.
Entré Incoming TCP Port
This option displays only if NET is chosen for the Entré connection. Enter the programming
port number for the incoming Entré connection. The programming port identifies the port
used to communicate messages to and from the Entré software. This port cannot be the
same port as programmed in Network Programming Port. The default Programming Port
setting is 2011.
Entré IP Address
This option displays only if NET is chosen for the Entré connection. Enter the Entré IP
address where the panel sends network messages. The Entré IP Address must be unique
and cannot be duplicated on the network. Enter all 12 digits and leave out the periods.
For example, enter IP address 192.168.0.250 as 192168000250. The periods display
automatically. Default is 0.0.0.0.
Entré Outbound TCP Port
This option displays only if NET is chosen for the Entré connection. Enter the programming
port number for the outbound Entré connection. The programming port identifies the port
used to communicate messages to the Entré software. Default is
2001.
Entré Backup Connection
This option displays if NET is chosen for the Entré connection. Enter the backup address
where the panel sends network messages if the first Entré connection fails. The Entré
connection must be unique and cannot be duplicated on the network. If the backup
connection is NET, enter all 12 digits and leave out the periods. The periods display
automatically. Default is 0.0.0.0.
Entré Backup TCP Port
This option displays only if NET or CELL is chosen for the Entré connection. Enter the
backup programming port number for the outbound Entré connection in case the
connection to the primary IP fails. Default is 2001.
Entre Reports
This option displays only if NET is chosen for the Entré connection. Choose which types of
system reports are sent to Entré. Press CMD to view all of the Entré report options. Choose
YES to enable zone, user code, or supervisory message reports. All Entré reports default to
YES.
Zone Reports
Zone reports send changes in the status of active zones. Includes the zone number, name,
type, the action (alarm, trouble, bypass, etc.), and user number (if applicable). If performing
a Walk Test, Zone Verify and Zone Fail messages are sent for each zone.
User Command Reports
Sends user code changes, schedule changes, and events.
Supervisory Reports
SECURECOM400
-
CELL APN:
ENTRE
CONNECTION: NONE
ENTRE INCOMING
TCP PORT: 2011
ENTRE IP
ENTRE OUTBOUND
TCP PORT: 2001
ENTRE BACKUP IP
-
ENTRE BACKUP TCP
PORT: 2001
ZONE: NO YES
ENTRE REPORTS
USER CMDS NO YES
SUPV MSG: NO YES