Digital Monitoring Products XF6 Series Installation and Programming Guide
40
programmer.
The STOP routine causes the following conditions to occur:
All 1100 Series DMP Wireless transmitters are reset to NORMAL
The panel Status List is cleared and all programming changes are saved
Missing LX-Bus™ Modules Displayed
The Programmer includes a feature following the STOP routine that displays the name of
any programmed LX-Bus module not currently connected to the panel.
Power Up
When the panel is powered up after an AC power failure, any zone transitions are not
recognized for 60 seconds. Normal zone processing resumes at the end of the 60 seconds.
SET LOCKOUT CODE
Set Lockout Code
Pressing CMD at the STOP option displays SET LOCKOUT CODE. This allows you to
program a code that is then required to gain access to the panel internal Programmer
through the keypad. You can change this code at any time to any combination of numbers
from three to five digits long. You do not need to enter leading zeros when using the
lockout code. Initializing the panel does not clear a Lockout Code. Lockout Codes can be
changed through Dealer Admin and Virtual Keypad.
SET LOCKOUT CODE