XF6 Series Installation and Programming Guide Digital Monitoring Products
27
Test, Zone Verify and Zone Fail messages are sent for each zone.
User Command Reports
Sends user code changes, schedule changes, and events.
Supervisory Reports
Sends system monitor reports, such as AC and battery, and system event reports.
Supervisory Reports also sends the • Alarm Bell Silenced * report.
Integrator Passphrase
To enable encryption enter an 8 to 16-character Passphrase using alphanumeric characters.
If you leave the Passphrase blank, the panel communicates with the integrator, but the data
is not encrypted. The Passphrase is blank by default.
App Key
Enter the 8-digit App Key obtained in your Dealer Settings tab at
dealer.securecomwireless.com.
This option is a security feature of the Virtual Keypad iPhone/Android App used only
when your Dealer Settings at dealer.securecomwireless.com have EASYconnect set as the
Communication Type.
This communication option is only available for panels with onboard network and is used to
eliminate the need for a static IP address programmed in Network Options. To enter a new
App Key, press any select key or area and enter any combination of 8 digits. Press CMD.
SYSTEM OPTIONS
System Options
This section allows you to select system-wide parameters.
USR CMDS: NO YES
SUPV MSG: NO YES
INTGRTR PASSPHRASE
-
APP KEY:
SYSTEM OPTIONS