Display Meaning/cause Troubleshooting/possible causes
In53 The toothed belt has jumped
Check toothed belt tension
Replace toothed belt if necessary
Carry out a teach-in run afterwards
In60 Panic lock active Deactivate panic lock
In61 Fire brigade function active Acknowledge fire brigade function
In62 Synchronous operation not working
Check wiring
Check second operator for correct parametrization
In63 Interlock mode not working (ES250/400 PRO only)
Check wiring
Check parametrization of the other door units
In 64 Fire protection closures Check fire alarm systems
In67 Sabotage warning CAN key switch
Check CAN key switch for sabotage
Replace CAN key switch if necessary
In68 Firmware download error Re-download firmware
In89 Battery is charging Battery is not functional in the event of a power failure
In97 Error I/O extension module
Reset the control unit
Check the wiring of theI/Oextension module
ReplaceI/Oextension module if necessary
In99 Unknown CAN device detected
Check the settings of all CAN devices (DIP switches) to check whether
third-party hardware is connected, perform CAN reset if necessary