Display Meaning/cause Troubleshooting/possible causes
E000 Control unit is error-free
E001 Door jammed in opening direction
Incorrect zeroing
Remove obstacle
Check floor guide
Check toothed belt
Adjust obstacle detection and force limitation settings
Check mechanics and electronics of locking device/drive
E002 Door jammed in closing direction
End stopper moved
Remove obstacle
Check floor guide
Check toothed belt
Adjust obstacle detection and force limitation settings
Check mechanics and electronics of locking device/drive
E003
Firmware versions do not match
(ES250/400 PRO FST only)
Check firmware version and WN of the control unit
Update firmware if necessary
E004 Inside detector error (ES250/400 PRO FST only)
Check wiring
Check the DIP switch settings on the EMSIAK
Check the DIP switch settings on the CAN sensors
if applicable, replace SiAK extension module
if applicable, replace CAN sensors
E005 Device identifier incorrect
Perform network reset*
If the error occurs again, replace the control unit
E006
Emergency open button not detected (on FIA locking device
only)
Mount emergency open button (CAN)
Check emergency open button (CAN) if necessary
E007 24V controller overvoltage/undervoltage
Perform network reset*
If the error occurs again, replace the control unit