ES 400 PRO/ES 400 PRO FST
Mounting instructions
Display Meaning/cause Troubleshooting/possible causes
E000 Control unit is error-free
E001 Door jammed in opening direction
Incorrect zeroing
Remove obstacle
Check floor guide
Check toothed belt
Adjust obstacle detection and force limitation settings
Check mechanics and electronics of locking device/drive
E002 Door jammed in closing direction
End stopper moved
Remove obstacle
Check floor guide
Check toothed belt
Adjust obstacle detection and force limitation settings
Check mechanics and electronics of locking device/drive
E003
Firmware versions do not match
(ES250/400 PRO FST only)
Check firmware version and WN of the control unit
Update firmware if necessary
E004 Inside detector error (ES250/400 PRO FST only)
Check wiring
Check the DIP switch settings on the EMSIAK
Check the DIP switch settings on the CAN sensors
if applicable, replace SiAK extension module
if applicable, replace CAN sensors
E005 Device identifier incorrect
Perform network reset*
If the error occurs again, replace the control unit
E006
Emergency open button not detected (on FIA locking device
only)
Mount emergency open button (CAN)
Check emergency open button (CAN) if necessary
E007 24V controller overvoltage/undervoltage
Perform network reset*
If the error occurs again, replace the control unit