ES 250 PRO/ES 250 PRO FST
ES 400 PRO/ES 400 PRO FST
Mounting instructions
Display Meaning/cause Troubleshooting/possible causes
E024 Unlock door lock
Locking device type adjusted correctly?
Locking device correctly adjusted mechanically?
Check wiring
E025 Lock the door lock
E026 Multi-point locking system
E027 General locking device error
E031 Operating mode switch
Check wiring and function of the operating mode switch
Replace operating mode switch if necessary
E032 FST operating mode switch (ES250/400 PRO FST only)
E034 EPS-CAN
E041 Sensor SCE 1
Check sensor wiring
Check sensor parameters
Replace sensor if necessary
E042 Sensor SCE 2
E043 Sensor MCE 1
E044 Sensor MCE 2
E049 CAN sensor
E051 Hall effect sensor
Check drive wiring
Replace drive if necessary
E052 Door position incorrect (ES250/400 PRO FST only)
Perform network reset*
Carrying out a teach-in run
E053 Toothed belt
Incorrect zeroing
End stopper moved
Check toothed belt tension
Replace toothed belt if necessary
Carry out a teach-in run afterwards
E054 Zero point detection failed
Check sensors and teach in again if necessary
Perform network reset*