Troubleshooting
125
10099206-AA
2201 Settings Corrupt Controller memory fault Cycle the Controller power and try again
or if unsuccessful, restore the printer to
‘Factory State’
2202 Variable Data Logging Stopped The variable data logging operation has stopped
as it has met the pre-programmed stop condition
Connect the Controller to CoLOS and
upload the Variable Data log from the
SmartDate
2203 Variable Data Log File Wrap
Around
The le space allocated for event logging is full
and the oldest entries in the log le are being
overwritten by the new entries
Connect the Controller to CoLOS and
upload the Variable Data log from the
SmartDate
2204 Variable Data Log Nearly Full The variable data logging operation is close to
the pre-programmed value
Connect the Controller to CoLOS and
upload the Variable Data log from the
SmartDate
2205 Calendar File Nearly Exhausted The pre-programmed calendar le is nearly
nished
Download a new calendar le to the
SmartDate
2206 Remote Job Database
Disconnected
A job has been selected but the required
database is not accessible
Conrm the connection to CoLOS and try
again
2207 File System Is Nearly Full The memory available for le storage is nearly
full
Delete unwanted les from the le system
2208 File System Is Full The memory available for le storage is full Delete unwanted les from the le system
2209 Firmware Upgraded The rmware was successfully upgraded and
the le system and settings restored
Clear warning and continue
2210 Firmware Upgrade Failed The rmware process was interrupted Clear warning and try again
2211 New Time/Date Codes File
Downloaded
New time/date codes le have been downloaded
to the controller
Clear warning and continue
2212 New Conguration Files
Downloaded
New conguration le has been downloaded to
the controller
Clear warning and continue
2213 Firmware Upgraded via USB The rmware was successfully upgraded using
a USB Memory Stick and the le system and
settings restored
Clear warning and continue
2214 New Printer Detected The Controller has detected connection to a
different Printer
Clear warning and continue
2215 New Print Width Detected A new printhead with a different print width has
been detected (SmartDate X45 Only)
Clear warning and continue
2218 System Settings Changed The Controller has detected changes to system
settings
Clear warning and continue
2219 Corrupt Language File The language could not be changed because the
language le is corrupt
Re-download the language le and retry
Temperature
Warning Possible Cause Corrective Action
2300 Printer High Temperature The Printer temperature is reaching it’s
maximum value
Slow the pack rate
2301 Controller High Temperature The Controller temperature is reaching it’s
maximum value
Slow the pack rate
2302 Printhead Under Temperature The temperature is below 13°C or less and may
be too low for good quality printing
Wait for the temperature within the printer
to rise above 13°C or start production,
inspecting the resulting prints until the
printhead temperature rises

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dover markem-image SmartDate X65 and is the answer not in the manual?

Dover markem-image SmartDate X65 Specifications

General IconGeneral
BrandDover
Modelmarkem-image SmartDate X65
CategoryPrinter
LanguageEnglish

Related product manuals